The Linear AP-5 is a versatile wireless access controller designed for various access control applications, including gates, doors, and barriers. It features a compact design and high-gain superheterodyne UHF receiver for reliable signal reception up to 500 feet. The AP-5 supports multiple transmitters and offers three relays for flexible configuration, making it ideal for residential and commercial use.
1.1 Overview of the Linear AP-5 Wireless Access Controller
The Linear AP-5 is a standalone wireless access controller designed for versatility in access control systems. It features a high-gain superheterodyne UHF receiver with an external antenna, enabling signal reception from transmitters up to 500 feet away. The device supports up to 480 Linear MegaCode transmitters and six Model MGT safety edge transmitters, stored in its memory. Its compact design and wireless functionality make it ideal for controlling door strikes, mag-locks, barrier gates, and automatic gates or doors in residential or commercial settings.
1.2 Applications of the Linear AP-5
The Linear AP-5 is ideal for controlling one or two door strikes, mag-locks, barrier gates, automatic gates, or door operators. It is suitable for residential, commercial, or industrial applications, offering reliable access control for vehicular gates, pedestrian access points, or industrial doors. Its wireless design simplifies installation in diverse settings, making it a versatile solution for various access management needs.
Key Features of the Linear AP-5
The Linear AP-5 features a high-gain superheterodyne UHF receiver with an external antenna, supporting up to 500 feet range and storing 480 MegaCode transmitters. It offers three configurable relays.
2.1 Types of Relays in the AP-5
The Linear AP-5 features three distinct relays: an access relay, an obstacle relay, and a configurable relay. The access relay controls entry points, while the obstacle relay ensures safety by halting operations when obstacles are detected. The third relay is versatile, allowing configuration for either access or obstacle functions, providing flexibility for various applications. These relays enable precise control over automated systems, ensuring smooth and secure operation of gates, doors, or barriers. Their design supports a wide range of access control scenarios, making the AP-5 highly adaptable for different setups.
2.2 Transmitter Compatibility and Range
The Linear AP-5 is compatible with MegaCode block-coded transmitters, supporting up to 480 devices. It also integrates with six Model MGT supervised safety edge transmitters. The system boasts a maximum wireless range of 500 feet, thanks to its high-gain superheterodyne UHF receiver and external antenna. This ensures reliable signal reception in various environments, making it suitable for both residential and commercial applications. The AP-5’s transmitter compatibility and extended range provide flexibility and efficiency for access control systems.
2.3 Wireless Connectivity and Signal Strength
The Linear AP-5 features a high-gain superheterodyne UHF receiver with an external antenna, enabling reliable wireless connectivity. It supports a maximum range of 500 feet, ensuring strong signal reception even in challenging environments. The device is optimized for MegaCode transmitters, storing up to 480 unique transmitter IDs for enhanced functionality. Its robust wireless performance minimizes interference, providing consistent and secure communication between transmitters and the controller. This makes the AP-5 ideal for applications requiring stable, long-range wireless access control in both residential and commercial settings.
2.4 Memory Capacity for Transmitters
The Linear AP-5 offers extensive memory capacity, supporting up to 480 Linear MegaCode transmitters. This allows for a large number of unique devices to be programmed and recognized by the controller. Additionally, it can store up to six Model MGT supervised safety edge transmitters, ensuring comprehensive obstacle detection capabilities. The AP-5’s memory capacity enhances scalability, making it suitable for both small-scale residential systems and larger commercial installations requiring multiple access points. This feature ensures efficient management of various transmitters, providing flexibility for diverse access control needs.
2.5 Configurable Relay Options
The Linear AP-5 features three separate relays, including one configurable relay that can be set to function as either an access or obstacle relay. This flexibility allows users to tailor the system to specific requirements, such as controlling door strikes, mag-locks, or barrier gates. The configurable relay enhances customization, enabling precise control over access points and safety mechanisms. This feature ensures the AP-5 can adapt to a wide range of access control scenarios, providing versatility for both residential and commercial applications.
Technical Specifications
The Linear AP-5 operates on the 315 MHz frequency with a high-gain superheterodyne UHF receiver, offering a 500-foot signal range. It supports up to 480 MegaCode transmitters and six MGT safety edge transmitters, ensuring reliable performance for various access control applications.
3.1 Operating Frequency and Receiver Type
The Linear AP-5 operates on the 315 MHz frequency, utilizing a high-gain superheterodyne UHF receiver for enhanced signal stability and range. This receiver type ensures reliable performance in various environments, providing a maximum signal reception range of up to 500 feet. The superheterodyne design minimizes interference, delivering clear and consistent communication between transmitters and the controller. This frequency and receiver combination is optimized for access control applications, supporting both residential and commercial installations with precision and durability.
3.2 Power Requirements and Environmental Considerations
The Linear AP-5 requires a 12V DC power supply, which can be sourced from a compatible transformer or battery. It is designed to operate efficiently in temperatures ranging from -20°F to 150°F (-29°C to 65°C), ensuring reliability in diverse environmental conditions. The device is built to withstand moderate humidity and dust, though it should be protected from direct exposure to harsh weather elements. Proper ventilation and mounting in a shaded area are recommended for optimal performance and longevity of the controller.
3.3 Dimensions and Weight
The Linear AP-5 is compactly designed for easy installation, measuring approximately 6.5 inches in length, 4.5 inches in width, and 1.5 inches in height. It weighs about 1.2 pounds, making it lightweight and suitable for mounting on various surfaces without adding significant strain. The device’s small footprint allows for discreet placement, ensuring it blends seamlessly into its environment while maintaining functionality. These dimensions and weight make the AP-5 ideal for both residential and commercial access control systems, providing a balance of performance and portability.
Installation Process
The Linear AP-5 installation involves a pre-installation checklist, step-by-step wiring, and safety precautions. Follow the manual for proper setup, ensuring secure and reliable access control functionality.
4.1 Pre-Installation Checklist
Before installing the Linear AP-5, ensure you have all necessary components, including the receiver, antenna, and power supply. Verify compatibility with your gate or door system and transmitters. Check the location for optimal signal strength, ensuring no obstructions. Review the manual for specific wiring diagrams and safety guidelines. Charge or install batteries as required. Ensure all tools are available, and familiarize yourself with the device’s features to streamline the installation process.
4.2 Step-by-Step Installation Instructions
Mount the AP-5 in a secure location, ensuring optimal antenna placement for signal strength. 2. Connect the receiver to a power supply, following the wiring diagram in the manual. 3. Install the external antenna to maximize signal reception. 4. Wire the relays to your gate or door system according to the application. 5. Program transmitters by adding their codes to the AP-5 memory. 6. Test the system to ensure proper functionality. Always follow safety precautions and consult the manual for specific configurations and diagrams;
4.3 Wiring Guidelines and Safety Precautions
Ensure proper wiring by following the diagram in the manual. Use the correct gauge wire for connections to avoid signal loss. Mount the AP-5 away from power lines to prevent interference. Disconnect power before wiring to avoid electrical shock. Secure all connections tightly to prevent loose wires. Follow local electrical codes and safety standards. Wear protective gear when handling wiring. Keep the area dry to prevent short circuits. Avoid overloading relays. If unsure, consult a licensed electrician for professional installation.
Programming the Linear AP-5
Programming the AP-5 involves adding transmitters, configuring relays, and setting up safety features. Follow the manual’s step-by-step guide for precise configuration and optimal functionality.
5.1 Adding Transmitters to the AP-5
To add transmitters, press and hold the AP-5’s learn button until the LED flashes. Activate the transmitter to synchronize it with the controller. The AP-5 can store up to 480 MegaCode transmitters and six MGT safety edge transmitters. Each transmitter is assigned to specific relays for operation. Follow the manual’s instructions for proper synchronization and assignment to ensure seamless functionality. This step is crucial for enabling remote access and control through authorized devices.
5.2 Configuring Relays for Specific Functions
The AP-5 allows customization of its three relays for specific functions. The access relay controls entry, the obstacle relay ensures safety, and the third can be configured for either function. To set up, assign transmitters to specific relays using the controller’s programming mode. This ensures each transmitter triggers the correct response. For example, a transmitter can activate the access relay for gate opening while another triggers obstacle detection. Proper configuration enhances functionality and safety, ensuring smooth operation for gates, doors, or barriers. Always test configurations to verify correct relay responses.
5.3 Setting Up Safety and Obstacle Detection
To enable safety and obstacle detection, configure the obstacle relay on the AP-5. This relay deactivates access when an obstacle is detected, ensuring safe operation. Program safety edge transmitters to trigger the obstacle relay, and test the system to verify proper function. The AP-5 supports up to six supervised safety edge transmitters, enhancing reliability. Use the controller’s programming mode to assign these transmitters to the obstacle relay. Regular testing ensures the system responds correctly, preventing accidents and ensuring compliance with safety standards. Proper setup is crucial for reliable performance.
Troubleshooting Common Issues
Identify issues like no signal reception or relay malfunctions by checking transmitter range, antenna alignment, and power supply. Consult the manual for diagnostic steps and solutions.
6.1 No Signal Reception from Transmitters
If the Linear AP-5 fails to receive signals from transmitters, ensure they are within the 500-foot range and properly programmed. Check the antenna for damage or misalignment. Verify that transmitters are powered on and synced with the AP-5. Physical obstructions or interference from other devices may disrupt signals. Restart the system and consult the manual for diagnostic steps to resolve connectivity issues. Ensure transmitter IDs are correctly stored in the AP-5 memory for reliable operation.
6.2 Relay Malfunction and Diagnostic Steps
If relays on the Linear AP-5 malfunction, check wiring connections for damage or corrosion. Ensure relays are configured correctly and not overloaded. Verify power supply and consult the manual for reset procedures. Test each relay individually to isolate issues. If problems persist, inspect for worn contacts or internal faults. Replace faulty relays as needed to restore proper functionality. Regular maintenance and updates can prevent such issues, ensuring reliable access control operations.
6.3 LED Indications and Error Codes
The Linear AP-5 uses LED indicators to display system status and errors. A steady green LED indicates power is on, while a flashing red LED signals no signal reception. Alternating red and green LEDs may indicate transmitter issues. Specific error codes, such as Code 1 for power faults or Code 2 for transmitter conflicts, provide detailed diagnostics. Refer to the manual for code interpretations and troubleshooting steps. These visual cues and codes help identify and resolve issues efficiently, ensuring optimal device performance and reliability. Regular monitoring of LED patterns can prevent prolonged system downtime.
Maintenance and Upkeep
Regular cleaning and inspection of the Linear AP-5 ensure optimal performance. Update firmware periodically and replace batteries as needed to maintain reliability and functionality over time.
7.1 Cleaning and Inspecting the Device
Regular cleaning and inspection of the Linear AP-5 ensure optimal performance. Use a soft, dry cloth to wipe the exterior and gently remove dust or debris. Inspect the antenna for damage or obstruction, as this can affect signal strength. Avoid using harsh chemicals or abrasive materials that may damage the device. Check for loose connections or wear on cables and ensure all components are secure. Perform these maintenance tasks periodically to prevent operational issues and extend the device’s lifespan.
7.2 Updating Firmware and Software
Regular firmware and software updates are essential for maintaining the Linear AP-5’s performance and security. To update, download the latest firmware from the official Linear website using a PC. Connect the AP-5 to your computer via the provided interface cable. Launch the firmware update software, select the device, and follow the on-screen instructions to complete the update. Ensure the device remains powered on during the process to avoid interruptions. Updating ensures compatibility with the latest features and security patches, keeping your system optimized and secure.
7.3 Replacing Batteries and Power Sources
To maintain optimal performance, replace the batteries in your Linear AP-5 as needed. First, disconnect the power source and remove the device’s casing to access the battery compartment. Identify the type of battery specified in the manual and replace it with a compatible model. Ensure proper reconnection of wires to avoid malfunctions. If using an external power supply, verify its compatibility and follow safety guidelines during replacement. Always refer to the manual for specific instructions to ensure a safe and successful process.
Integration with Smart Systems
The Linear AP-5 seamlessly integrates with smart systems like Remootio, enabling smartphone control via Wi-Fi or Bluetooth. This enhances convenience and modernizes access control management.
8.1 Using Remootio for Smart Control
The Linear AP-5 is compatible with Remootio, a Wi-Fi and Bluetooth smart gate opener accessory. This integration allows users to control their gates or doors remotely using a smartphone app. Remootio enhances convenience by enabling seamless operation from anywhere, eliminating the need for physical keys or remotes. It also supports voice commands through smart home systems like Alexa or Google Assistant. With Remootio, users can monitor gate status, receive notifications, and grant access to guests remotely, making it a modern and efficient solution for access control.
8.2 Compatibility with Smart Home Systems
The Linear AP-5 seamlessly integrates with popular smart home systems, enhancing its functionality and user convenience. It is compatible with systems like Amazon Alexa and Google Assistant, allowing voice command control for gates and doors. Additionally, the AP-5 works with smart home hubs, enabling centralized control of multiple devices. This integration allows users to monitor and manage their access points remotely through smartphone apps, ensuring enhanced security and convenience. The AP-5’s compatibility with smart home systems makes it a versatile and modern solution for automated access control.
Security Features
The Linear AP-5 employs advanced security measures, including MegaCode signals and rolling code technology, to ensure encrypted communication and prevent unauthorized access. It supports up to 480 secure transmitters and supervised safety edge transmitters for enhanced protection and obstacle detection, ensuring reliable and secure operation of access control systems.
9.1 Encryption and Signal Security
The Linear AP-5 utilizes MegaCode signals, a advanced rolling code technology, to ensure secure communication between transmitters and the controller. This encryption method prevents unauthorized access by generating unique codes for each transmission, making it difficult for signals to be intercepted or duplicated. The system supports up to 480 MegaCode transmitters, each with a unique identifier, enhancing security and minimizing the risk of unauthorized entry. Additionally, the AP-5’s signal security features include supervised safety edge transmitters, further safeguarding against obstacles and ensuring reliable operation.
9.2 Access Control Best Practices
To ensure optimal security and functionality, it is recommended to change default settings and use strong, unique codes for transmitters. Regularly update firmware to protect against vulnerabilities and maintain system integrity. Physically secure the AP-5 to prevent tampering. Test all configurations thoroughly to verify proper operation. Keep detailed documentation of transmitter assignments and settings for troubleshooting and compliance. Regular audits of access permissions and signal strength can enhance overall security and performance, ensuring reliable and safe operation of the Linear AP-5 access control system.
Compatible Devices and Accessories
The Linear AP-5 is compatible with MegaCode transmitters, safety edge transmitters, and optional accessories like Remootio for smart control. It supports up to 480 transmitters and enhances functionality with additional hardware.
10.1 List of Compatible Transmitters
The Linear AP-5 is compatible with up to 480 MegaCode transmitters, ensuring secure and reliable communication. It supports Model MGT supervised safety edge transmitters, enhancing obstacle detection. The device works seamlessly with Linear’s block-coded transmitters, including keychain remotes and wall-mounted units. Its compatibility extends to a variety of access control systems, making it versatile for residential and commercial applications. The AP-5’s transmitter support ensures flexibility and scalability, catering to diverse access control needs while maintaining high security standards.
10.2 Optional Accessories for Enhanced Functionality
Enhance the functionality of your Linear AP-5 with optional accessories like the Remootio smart control system, enabling smartphone operation. Safety edge transmitters improve obstacle detection, while external antennas boost signal range. Additional keypads and proximity readers provide alternative access methods. Backup power sources, such as batteries, ensure operation during outages. These accessories expand the AP-5’s capabilities, offering tailored solutions for specific needs, from smart integration to advanced security features, ensuring a robust and adaptable access control system.
FAQs
- What is the maximum number of transmitters the AP-5 can store? Up to 480.
- What is the maximum signal range? Signals can be received up to 500 feet away.
- Is the AP-5 compatible with smart systems? Yes, it works with Remootio for smartphone control.
- Why is my AP-5 not receiving signals? Check antenna placement and transmitter compatibility.
11.1 Common Questions About the AP-5
How many transmitters can the AP-5 store? It can store up to 480 Linear MegaCode transmitters.
What is the maximum signal range? Signals can be received from up to 500 feet away.
Is the AP-5 compatible with smart systems? Yes, it works with Remootio for smartphone control.
Why isn’t my AP-5 receiving signals? Check antenna placement, transmitter compatibility, and ensure no obstacles block the signal.
Can the AP-5 control multiple devices? Yes, it supports one or two door strikes, mag-locks, or barrier gates.
How do I update the firmware? Refer to the manual for step-by-step firmware update instructions.
Is the AP-5 suitable for outdoor use? Yes, but ensure proper environmental considerations for optimal performance.
What if the relays malfunction? Consult the troubleshooting section in the manual for diagnostic steps.
The Linear AP-5 is a reliable and versatile wireless access controller designed for a wide range of applications, including gates, doors, and barriers; With its high-gain superheterodyne receiver and 500-foot signal range, it offers robust performance for both residential and commercial use. Its compatibility with smart systems like Remootio and ability to store up to 480 transmitters make it a flexible solution for modern access control needs. By following the manual and troubleshooting guides, users can ensure optimal functionality and security for their systems.